מודול הרחבת לולאה NORDEN NFA-T01LM
מידע על המוצר
מפרטים
- הַתאָמָה: EN 54 Part 18 (European Standard)
- קלט כרךtage: DC24V
- Bus Input Range: 1000 מטר
הוראות שימוש במוצר
הַתקָנָה
- הכנת התקנה
This interface module must be installed, commissioned, and maintained by qualified or factory-trained service personnel. Ensure compliance with all local codes in your area or standards like BS 5839 Part 1 and EN54. - התקנה וחיווט
- Install the loop extension module where anti-interference is needed or for extending bus communication distance within 1000m.
- Securely fix the module with screws in a suitable location.
- Refer to the external wiring terminal diagram for proper wiring.
Loop Extension Module Configuration
- Outline Dimension Chart
Refer to the outline dimension chart for the physical size of the loop extension module. - עקרון עבודה
The loop extension module collects bus signals, processes them through the MCU to output a standard bus waveform. The signal isolation circuit extends the bus communication distance and corrects the bus waveform through an optocoupler.
כתב ויתור
כֹּל הַזְכוּיוֹת שְׁמוּרוֹת.
המידע במסמך זה נתון לשינויים ללא הודעה מוקדמת
בטיחות המוצר
כדי למנוע פציעה חמורה ואובדן חיים או רכוש, קרא בעיון את ההוראות לפני התקנת הגלאי כדי להבטיח פעולה תקינה ובטוחה של המערכת.
מָבוֹא
מֵעַלview
- מודול הרחבת הלולאה NFA-T01LM פועל על ספק כוח DC24V ומשתמש במעגל בידוד חשמלי פנימי כדי להשיג בידוד בזמן אמת ושידור של אותות אפיק קלט ופלט, ומספק צורת גל סטנדרטית של אפיק. מודול זה משפר את עמידות האפיק להפרעות ומסייע בהרחבת טווח התקשורת. הוא יעיל במיוחד בסביבות בהן מתרחשות הפרעות חיצוניות או בהן נדרשים מרחקי תקשורת ארוכים יותר.
- היחידה, העומדת בתקן EN 54 חלק 18 (תקן אירופאי), כוללת עיצוב דיסקרטי המתאים לבניינים מודרניים. הרכבתה הנשלפת מאפשרת התקנה ותחזוקה קלים. היא תואמת באופן מלא ללוח בקרת גילוי אש חכם מסוג NFA-T04FP, ומבטיחה תקשורת חלקה ללא בעיות תאימות.
תכונות ויתרונות
- תאימות EN54-18
- Built-in MCU processor
- Input bus, the output bus signal between the electrical isolation, electromagnetic interference has a good inhibitory capacity, stable and reliable work. Input Fire or Supervisory signal configuration.
- מחוון מצב LED
- To correct the bus signal, the output standard bus waveform
- Fast intelligent bus output short circuit judge function, bus output short circuit protection function; after the bus is normal, it can recover the bus output in time
- עיצוב אסתטי
מפרט טכני
| הַתאָמָה | EN 54-18:2005 |
| קלט כרךtage | Loop Power:24VDC [16V to 28V]
External PSU: 20 to 28VDC |
| צריכה נוכחית | Loop: ≤5mA
External PSU: ≤500mA |
| Bus input range: ≤1000m | Bus output range: ≤1000m |
| Most cascade | שְׁלוֹשָׁה |
| Protocol/Addressing | Norden, Value ranges from 1 to 254 |
| מצב מחוון | Normal: Single blink/Fault: Steady-on |
| Material / Colour | Metal / Gray |
| Dimension / LWH | 155.0 מ"מ × 97.0 מ"מ × 40.0 מ"מ |
| טמפרטורת הפעלה | -10 מעלות צלזיוס עד +55 מעלות צלזיוס |
| לַחוּת | 0 to 95% Relative Humidity, Non-condensing |
הַתקָנָה
הכנת התקנה
This interface module must be installed, commissioned, and maintained by a qualified or factory-trained service personnel. The installation must be installed in compliance with all local codes having jurisdiction in your area, or BS 5839 Part 1 and EN54.
התקנה וחיווט
- The loop extension module is used for anti-interference. When used outside the site should be installed in the presence of disturbances, such as the shielding effect of the iron shell. , extension module as an extended bus communication distanc, is used; it should be installed at the output end of long long-distance bus controller within 1000m; fixed by screws, installed in the room.
- The external wiring terminal diagram is shown below:

- D1, D2: מסוף כניסת מתח 24V
- I1, I2: Bus input terminal
- 01, 02: Bus output terminal, 01 is the positive, 02 is the negative.
- דרישות חיווט: no polarity signal, two buses using RVS twisted pair,
- Sectional area≥1.0mm²;
- DC24V power using BV line, Sectional area≥1.5mm²
NOTE: The NFA-T01LM cannot be used in the loop.
Loop extension module configuration
Outline dimension chart

עקרון עבודה
The loop extension module collects the bus signal through the bus transceiver circuit, and outputs the control bus output circuit after the MCU processes the standard bus waveform; the signal isolation circuit bus input and output through an optocoupler can extend the bus communication distance and can correct the bus waveform.
שימוש ותפעול
- The use of the loop extension module must follow the following requirements:
Meet the technical parameters defined in this specification - After the loop extension module is installed, or in the use of the process to be tested every six months, the test method is as follows:
- The fire alarm controller is used to connect the front-end coding device with the extension module, and the coding equipment should be able to log in correctly.
- The detector, which is connected to the bus through the extension module is reports to the fire alarm, and the controller should be able to receive the alarm information correctly.
טיפול ואחסון
Transport, storage, and handling equipment shall be carried out in a packing condition. Loading and unloadprocessescess must be handled with care to prevent collision damage. StorageThehe environment shouldmaintainedn ventilation, dry, and avoid open storage.
תחזוקה כללית
- הודע לצוות המתאים לפני ביצוע התחזוקה.
- Disable the loop extension module on the control panel to prevent false alarms.
- Do not attempt to repair the circuitry of the loop extension module; it may affect the operation to respond to a fire condition and will void the manufacturer’s warranty.
- Notify again proper personnel after conducting the maintenance, and make sure to enable the loop extension module and confirm if up and running.
- Perform the maintenance semiannually or depending on the site conditions.
שיקולים מרכזיים
- On-duty personnel should be familiar with the operation of the equipment, not the wrong operation.
- This module for fire protection products must strictly implement the duty system and the shift in use, and make a running record.
- Not every half a year is a function of the module test.
נספח 1
Limitations of the Loop extension module
- The loop extension module cannot last forever. To keep the loop extension module working in good condition, please maintain the equipment continuously according to recommendations from manufacturers and relevant national codes and laws. Take specific maintenance measures based on different environments.
- This loop extension module contains electronic parts. Even though it is made to last for a long period of time, any of these parts could fail at any time. Therefore, test your module at least every half-year according to national codes or laws. Any loop extension module, fire alarm devices, or any other components of the system must be repaired and/or replaced immediately as they fail.
אודות החברה
- Norden Communication UK Ltd
- 18th & 19th Floor, 100 Bishopsgate, London EC2N 4AG , United Kingdom
- business@nordencommunication.com
- www.nordencommunication.com
שאלות נפוצות
מהו נפח הקלטtagמהי הדרישה עבור מודול הרחבת הלולאה NFA-T01LM?
The module operates on a DC24V power supply.
How far can the bus input range of the module extend?
The bus input range can extend up to 1000m.
מסמכים / משאבים
![]() |
מודול הרחבת לולאה NORDEN NFA-T01LM [pdfמדריך הוראות NFA-T01LM, מודול הרחבת לולאה NFA-T01LM, מודול הרחבת לולאה, מודול הרחבה, מודול |