1. הקדמה
This manual provides essential information for the safe operation, maintenance, and troubleshooting of your maXpeedingrods MXR2850 2850 Watt Portable Inverter Generator. Please read this manual thoroughly before operating the generator to ensure proper use and to prevent injury or damage.
The maXpeedingrods MXR2850 is a 4-stroke OHV gasoline inverter generator designed for various applications, including camping, outdoor events, RV use, and home power backup. It delivers 2850W maximum watts and 2200W running watts, providing clean power suitable for sensitive electronics.

2. מידע בטיחות חשוב
Always follow these safety guidelines to prevent serious injury or death.
- סכנת פחמן חד חמצני: Generators produce carbon monoxide (CO), a colorless, odorless, poisonous gas. Operate the generator ONLY outdoors and far away from windows, doors, and vents. Never operate indoors, in a garage, or in any enclosed space.
- סכנת שריפה: בנזין דליק ביותר. יש למלא דלק באזור מאוורר היטב כאשר המנוע כבוי ומקורר. אין לעשן או לאפשר להבות גלויות בקרבת הגנרטור.
- סכנת התחשמלות: לעולם אל תפעילו את הגנרטור בתנאים רטובים. ודאו שכל החיבורים החשמליים יבשים ומוארקים כראוי.
- משטחים חמים: מנוע הגנרטור ומשתיק הקול מתחממים מאוד במהלך הפעולה ונשארים חמים זמן מה לאחר הכיבוי. יש להימנע ממגע עם משטחים חמים כדי למנוע כוויות.
- ילדים וחיות מחמד: הרחיקו ילדים וחיות מחמד מהגנרטור, במיוחד במהלך הפעולה.
- קרא את המדריך: יש לקרוא ולהבין תמיד את כל מדריך ההוראות לפני הפעלת הגנרטור.
3. רכיבי ותכונות המוצר
Familiarize yourself with the key components and features of your MXR2850 generator.
3.1 לוח הבקרה נגמרview

- VFRT Meter: מציג נפחtage, Frequency, Running Time (single and cumulative).
- CO Alert: Carbon Monoxide detection indicator.
- מחוון שמן נמוך: Illuminates when oil level is low.
- מחוון פלט AC: Shows when AC power is available.
- מחוון עומס יתר: Illuminates if the generator is overloaded.
- מתג ראשי: ON/OFF switch for the generator.
- מתג מצב ECO: מפעיל מצב חסכוני לחיסכון בדלק.
- לחצן איפוס: Resets the generator in case of overload.
- שקעי USB: Two 5V 2.1A/1A USB ports for charging devices.
- AC 120V/20A Outlets: Two standard AC outlets.
- יציאות מקביליות: For connecting two generators in parallel (parallel box sold separately).
- Grounding Nut: לצורך הארקה נכונה של הגנרטור.
3.2 תכונות עיקריות
- Multifunction Power Supplier: 2850W max watts and 2200W running watts, suitable for camping, festivals, tailgating, caravans, and home power backup.
- Intelligent Digital Display Meter: Easily monitor voltage, frequency, and accumulated running time for convenient maintenance.
- Extra Long Runtime: Runs 7 hours at 25% load (550W) and 5 hours at 50% load (1100W). Eco mode extends runtime to 10-12 hours.
- Clean Current: Inverter technology provides stable, clean power for sensitive electronics like phones, laptops, and cameras.
4. הגדרה ראשונית
לפני הפעלת הגנרטור בפעם הראשונה, בצע את השלבים הבאים:
4.1 הוספת שמן מנוע
- Remove the maintenance cover by loosening the screws.
- Unscrew and remove the oil dipstick.
- Using the provided oil funnel, add 350ml of new SAE 10W-30 engine oil. Do NOT overfill; the oil level should not exceed the "H" position on the dipstick.
- Tighten the oil dipstick securely.
- התקן מחדש את מכסה התחזוקה.
4.2 Add Gasoline
- הסר את מכסה הדלק.
- Add E10 gasoline. The gasoline level should NOT be higher than the red ring inside the fuel tank. The fuel tank capacity is 1.1 gallons.
- הדק בזהירות את מכסה מיכל הדלק.

5. הוראות הפעלה
5.1 הפעלת הגנרטור (התנעה חוזרת)
- Turn the three-in-one switch to the "CHOKE" position.
- Ensure the ECO switch is in the "OFF" position.
- אחוז בחוזקה ומשוך את ידית הרתיעה באיטיות עד שתרגיש התנגדות מוגברת, ואז משוך במהירות.
- Once the engine starts and runs smoothly, turn the engine switch to the "RUN" position.
- After the AC indicator turns green, plug in your device.
5.2 עצירת הגנרטור
- Remove all loads from the output receptacles.
- Turn the three-in-one switch to the "OFF" position.
- הוֹדָעָה: Always turn off the main power switch on the control panel after use. A drained battery will prevent the generator from starting.
6. תחזוקה
תחזוקה שוטפת מבטיחה את אורך חייו של הגנרטור וביצועיו האופטימליים.
6.1 Clean the Air Filter
- הסר את מכסה מסנן האוויר.
- Take out the sponge air filter element.
- Wash the filter element in household detergent and warm water.
- Use a clean cloth to slowly squeeze out excess water, then air dry naturally.
- Spray some engine oil on the filter element. Use a clean absorbent cloth to squeeze out excess oil.
- Place the air filter element in the assembly and install the air cleaner cover.

6.2 Drain the Gasoline for Storage
If storing the generator for an extended period, drain the gasoline to prevent fuel degradation issues.
- Turn the three-in-one switch to the "RUN" position.
- Loosen the drain bolt counterclockwise on the carburetor.
- Allow gasoline to drain into a suitable container.
- After discharging gasoline, tighten the drain bolt clockwise.
- Install the maintenance cover.
6.3 Replace the Spark Plug
- הסר את מכסה תחזוקת המצת.
- Pull off the spark plug cap.
- Turn the spark plug wrench counterclockwise to remove the old spark plug.
- Install the new spark plug clockwise using the wrench.
- Fasten the spark plug maintenance cover.

7. פתרון תקלות
If your generator encounters issues, refer to the following common troubleshooting steps. For complex problems, contact customer service.
7.1 Generator Cannot Recoil Start (First Use)
- בדוק מפלס שמן: Ensure the oil level is correct and not overfilled. If the low oil indicator light is still yellow after filling, disconnect the oil sensor connector (this will disable the low oil warning function).
- Check Fuel System: Verify that the entire fuel system is unobstructed. Turn the fuel switch to the "ON" or "RUN" position. Locate the carburetor and loosen the drain bolt counterclockwise to allow gasoline to drain. If gasoline flows continuously, the system is fine. If it flows intermittently or very little, the fuel system is obstructed. Check if the fuel pipe is folded or bent and correct it.
- Check Circuit System: Remove the spark plug maintenance cover and check if the spark plug cap is inserted properly. Take out the spark plug and check for damage; replace if necessary. Check if the spark plug ignites when starting the generator (hold the spark plug against the engine case, but do not touch with bare hands due to electric shock risk). If there is no spark, check for loose or damaged plug boxes.
- Check Carburetor Choke Operation: (Applicable to recoil start models only) Locate the throttle stepper motor above the carburetor. Turn the three-in-one switch to the "RUN" position. Loosen the fixing bolts on the carburetor and let the throttle assembly automatically return to the fully open position. Pull the cable to ensure the choke cable is straight, then tighten the cable fixing bolts. Turn the three-in-one switch to the choke position and observe whether the choke position is correct.
If the above checks cannot solve your problem, please contact our customer service.
8. מפרטים
| תכונה | מִפרָט |
|---|---|
| מותג | maXpeedingrods |
| מספר דגם | MXR2850 |
| מהtage (מקסימום) | 2850 וואט |
| מהtagה (ריצה) | 2200 וואט |
| סוג דלק | Gasoline (E10 Recommended) |
| מקור כוח | מופעל על גז |
| שימושים מומלצים | Camping, Outdoor, RV Ready |
| משקל פריט | 46.2 פאונד (20950 גרם) |
| כרך ידtage | 120 וולט |
| תכונה מיוחדת | Overload Protection, CO Alarm |
| רכיבים כלולים | Charging Cable, Owner Manual, Oil Funnel, Spark Plug Socket Wrench, Screwdriver, US Plug |
| צֶבַע | אָדוֹם |
| סוג מנוע | 4 פעימות |
| סוג מערכת הצתה | התחל להרתיע |
| נפח מיכל | 1.1 ליטר |
| נפח מנוע | 79.7 סנטימטר מעוקב |
| מידות המוצר | 20.47 x 13.74 x 20.12 אינץ' |
9. אחריות ותמיכה
maXpeedingrods warrants all inverter generators against defects in workmanship under normal use for a period of 2 years from the date of retail purchase by the original end-user purchaser ("Warranty Period").
Free lifetime technical support and customer service are provided. For any issues not covered in this manual, please contact maXpeedingrods customer service.