1. הקדמה
This manual provides essential information for the safe and efficient operation, installation, and maintenance of your VEVOR Above Ground Pool Pump, Model HAP750. Please read this manual thoroughly before installation and use, and retain it for future reference.
2. מידע בטיחות
Always follow basic safety precautions to reduce the risk of fire, electric shock, and injury to persons.
- Ensure the pump is installed by a qualified professional in accordance with all local and national electrical codes.
- יש לנתק תמיד את החשמל למשאבה לפני ביצוע כל תחזוקה או שירות.
- Do not run the pump dry. Ensure the pump is filled with water before starting.
- Install the pump at least 10 feet (3 meters) from the inside walls of the pool.
- Use an extension cord only if absolutely necessary and ensure it is rated for outdoor use and the pump's power requirements.
- The pump is designed for use with permanently installed pools and spas. It should not be used with storage tanks.
- Ensure proper grounding. The pump incorporates grounding terminals to connect to ground lines for added security.
3. המוצר נגמרview
The VEVOR Above Ground Pool Pump, Model HAP750, is a single-speed, 1HP pump designed for efficient water circulation and filtration in above-ground pools, hot tubs, and spas.
3.1 תכונות עיקריות
- 1 HP Premium Copper Motor: Operates at 120V / 60Hz with 3450 RPM, featuring an aluminum motor casing and built-in thermal protection for stable and efficient performance.
- Corrosion-Resistant Thickened Shell: Constructed with a durable PP shell and integrated structure, ensuring leak-free and wear-resistant properties, even with disinfectant-treated water.
- Efficient Water Circulation System: Delivers a maximum water flow of 80 GPM and a maximum head lift of 36 ft (11 m) for rapid water circulation.
- Detachable Filter Basket: Facilitates physical purification, compatible with a sand filter (not included). A transparent PVC cover allows easy monitoring for cleaning.
- אבטחה משופרת: Includes grounding terminals for connecting to ground lines.
- יישום רב תכליתי: Suitable for above-ground pools, hot tubs, spas, and irrigation systems. Not recommended for storage tanks.
3.2 רכיבים
The pump unit typically includes the motor, pump housing with a filter basket, and connection adapters.

This image displays the main pump unit, featuring the motor, pump housing with a clear lid for the filter basket, and several connection adapters for different hose sizes. The pump is black with a metallic motor housing.

This diagram highlights key components of the pump, including the water inlet, water outlet, pump body, detachable transparent lid, grounding terminal, strainer basket, ventilation fan, stable base, and drain plug. It illustrates the integrated corrosion-resistant casing.
4. התקנה והתקנה
התקנה נכונה היא קריטית לביצועי המשאבה ולאורך החיים שלה. יש לבצע את השלבים הבאים בקפידה.
4.1 בחירת אתר
- Place the pump on a firm, level surface, ensuring it is at least 10 feet (3 meters) from the pool's edge.
- Ensure the location is well-ventilated and protected from direct sunlight and harsh weather conditions.
- The pump should be positioned below the water level of the pool to facilitate priming.
4.2 חיבור לחשמל
The VEVOR HAP750 pump operates on 120V / 60Hz. All electrical wiring must be performed by a licensed electrician and comply with local and national electrical codes.
- ודא שספק הכוח תואם את עוצמת הקול של המשאבהtagדרישות e (120V).
- Connect the pump to a dedicated, grounded circuit protected by a Ground Fault Circuit Interrupter (GFCI).
- Utilize the provided grounding terminals to ensure the pump is properly grounded.
This video demonstrates the process of connecting the power cord to a pool pump. It shows opening the junction box, connecting the live, neutral, and ground wires to their respective terminals, and then securing the junction box cover. While the video features a dual-speed pump, the wiring principles for a single-speed pump are similar for the power connection.
4.3 חיבור אינסטלציה
- Connect the pool's skimmer line (suction) to the pump's inlet.
- Connect the pump's outlet to the pool's return line (to the filter, then back to the pool).
- Use appropriate hose adapters (1-1/2" and 2" connection adapters are typically included) and hose clamps to ensure a watertight seal.
- ודאו שכל החיבורים מהודקים היטב כדי למנוע דליפות אוויר, אשר עלולות לפגוע בביצועי המשאבה.

This image illustrates the pump with different hose adapters, emphasizing the flexibility in connecting to various plumbing setups. The adapters are crucial for ensuring a secure and leak-free connection between the pump and the pool's filtration system.
5. הוראות הפעלה
5.1 התחלת המשאבה
Before starting the pump for the first time or after draining, it must be primed to ensure it is filled with water and free of air.
- Ensure all valves are open, allowing water to flow from the pool to the pump.
- Remove the transparent lid from the strainer basket.
- Fill the strainer basket housing completely with water.
- Replace the lid, ensuring it is securely tightened to create an airtight seal.
- Turn on the pump. It should begin to draw water from the pool.
- If the pump does not prime within a few minutes, turn it off, re-fill the strainer housing, and repeat the process.
5.2 הפעלת המשאבה
Once primed, the pump is ready for operation.
- Ensure all plumbing connections are secure and leak-free.
- Verify that the filter system (if applicable) is correctly set for filtration.
- Turn on the power to the pump. The pump will begin circulating water.
This video showcases a single-speed pool pump in operation, demonstrating the water circulation and the ease of installation of connection adapters. It highlights the pump's powerful performance and easy maintenance features, including the filter basket.
6. תחזוקה
תחזוקה שוטפת מבטיחה ביצועים אופטימליים ומאריכה את חיי המשאבה.
6.1 Cleaning the Strainer Basket
The detachable filter basket should be checked and cleaned regularly, especially if water flow decreases or the transparent lid shows accumulated debris.
- כבה את המשאבה ונתק את החשמל.
- Unscrew and remove the transparent lid.
- הרם החוצה את סל המסננת.
- Empty any debris and rinse the basket thoroughly with water.
- בדוק את טבעת ה-O שעל המכסה לאיתור סדקים או בלאי; החלף במידת הצורך.
- Place the clean basket back into the housing, ensuring it seats properly.
- Replace the lid and tighten securely.
- Re-prime the pump if necessary before restarting.

תמונה זו מספקת תמונה ברורה view of the detachable strainer basket inside the pump housing, illustrating its function in capturing debris like leaves and small stones to prevent them from entering the pump or filter system.
6.2 החורף
In colder climates, proper winterization is essential to prevent damage from freezing.
- רוקנו את כל המים מהמשאבה ומהצנרת.
- Remove the drain plug from the pump housing.
- Store the pump in a dry, protected area during the off-season.
7. פתרון תקלות
אם נתקלת בבעיות עם המשאבה שלך, עיין בבעיות הנפוצות ובפתרונות הבאים:
| בְּעָיָה | סיבה אפשרית | פִּתָרוֹן |
|---|---|---|
| המשאבה לא מתחילה | No power; tripped GFCI; motor overload. | Check power supply; reset GFCI; allow motor to cool and reset thermal protection. |
| המשאבה פועלת אך אין זרימת מים | Pump not primed; air leak in suction line; clogged strainer basket. | Prime the pump; check all suction line connections for leaks; clean strainer basket. |
| זרימת מים נמוכה | Clogged strainer basket; dirty filter; air leak. | Clean strainer basket; backwash/clean filter; check for air leaks. |
| רעש/רעידות יתר | Air leak; cavitation; loose mounting. | Check for air leaks; ensure adequate water supply to pump; tighten mounting bolts. |
8. מפרטים
| תכונה | מִפרָט |
|---|---|
| מותג | VEVOR |
| מספר דגם | HAP750 |
| כּוֹחַ | 1 HP |
| כרך ידtage | 120V / 60Hz |
| מהירות סיבוב | 3450 סל"ד |
| קצב זרימה מקסימלי | 80 GPM |
| הרמת ראש מקסימלית | 36 רגל / 11 מ' |
| חוֹמֶר | Aluminum, Polypropylene (PP) |
| צֶבַע | שָׁחוֹר |
| משקל פריט | 22.93 פאונד |
| מידות המוצר | 24.4 x 10 x 11.4 אינץ' |
| אורך כבל | 35.4 אינץ' / 0.9 מ' |
| Compatible Sand Filter Size | 16-19 אינץ' (לא כלול) |
| Maximum Pool Capacity | 27,000 ליטר |

This graphic provides a visual overview of the pump's physical dimensions and a table summarizing its key technical specifications, including model number, voltage, power, rotating speed, max head lift, max water flow, cord length, compatible sand filter size, and maximum pool gallons.
9. אחריות ותמיכה
For warranty information or technical support, please refer to the product packaging or contact VEVOR customer service directly. Keep your purchase receipt for warranty claims.