מָבוֹא
This manual provides essential information for the safe and efficient operation, installation, and maintenance of your Goodman Mini-Split AC/Heating System E-Series. Please read this manual thoroughly before installation and use, and retain it for future reference. This system is designed to provide efficient heating and cooling for residential and light commercial applications.
התקנה והתקנה
The Goodman Mini-Split AC/Heating System E-Series includes an indoor wall-mounted air handler unit, an outdoor mini-split heat pump condenser, and a comprehensive installation kit. Professional installation is recommended for optimal performance and safety.
רכיבים כלולים
- Indoor Wall Mounted Air Handler Unit
- Outdoor Mini Split Heat Pump Condenser
- Line Set (30-foot length, 1/4 x 3/8 copper lines)
- חוט בקרה
- Wall Mount Bracket (18 1/4" Length)
- Line Cover Guards
- Drain Tube (20-foot)
- שלט רחוק אלחוטי

איור 1: מעלview of the Goodman Mini-Split AC/Heating System E-Series and its included components, showing the indoor unit, outdoor unit, remote control, and installation kit elements.
שיקולי התקנה
Ensure the installation area for both indoor and outdoor units meets the required clearances for proper airflow and maintenance. The system operates on 208/230V, 1 Phase, 60Hz power. The 0.75-ton unit is designed to efficiently heat and cool areas up to 400 square feet.

איור 2: מפורט view of the ACiQ Mini Split Installation Kit, including line sets, control wire, drain tube, wall mount bracket, and line cover guards.
הוראות הפעלה
Your Goodman E-Series Mini-Split system offers various modes and features for optimal comfort and energy efficiency.
מצבי פעולה בסיסיים
- מצב קירור: Reduces room temperature to the desired setting.
- מצב חימום: Increases room temperature to the desired setting.
- מצב מאוורר: מזרים אוויר ללא חימום או קירור.
- מצב ייבוש (הסרת לחות): מפחית לחות בחדר.
- מצב אוטומטי: Automatically selects heating or cooling based on the set temperature and current room temperature.
תכונות ובקרות עיקריות
- Wireless Backlight Remote Control: Allows convenient adjustment of settings from anywhere in the room.
- Auto-Restart After Power Failure: היחידה תחזור לפעול באופן אוטומטי עם ההגדרות הקודמות לאחר הפסקת חשמל.tage.
- Self-Diagnosis with Digital Display: Provides error codes on the digital display for easier troubleshooting.
- Adjustable LED Display ON/OFF: Control the visibility of the unit's LED display.
- Power Saving Sleep Mode Set-up: Optimizes temperature and fan speed for comfortable sleep while conserving energy.

Figure 3: Illustration of the key features of the Goodman E-Series Mini-Split system, including remote control, auto-restart, self-diagnosis, and various operational modes.
תַחזוּקָה
Regular maintenance ensures the longevity and efficient operation of your mini-split system. Always disconnect power to the unit before performing any maintenance.
ניקוי מסננים
The system is equipped with a Catechin Air Quality Filter System and a Titanium Apatite Deodorising Filter. These filters should be cleaned regularly, typically every 2-4 weeks depending on usage and air quality. Refer to the specific instructions in your full product manual for filter removal and cleaning procedures. Generally, filters can be gently vacuumed or washed with lukewarm water and mild detergent, then air-dried completely before reinstallation.
Drain Pan Maintenance
The indoor unit features a removable dirt-water drain pan. Periodically inspect and clean the drain pan to prevent mold growth and blockages, which can lead to water leaks. Ensure the drain tube is clear and free of obstructions.
ניקוי יחידות
The indoor unit has a wipe-clean flat panel. Use a soft, damp cloth to clean the exterior surfaces. Do not use harsh chemicals or abrasive cleaners. For the outdoor unit, ensure the coils are free of debris and obstructions. The outdoor unit also features anti-corrosion treatment for enhanced durability.
פתרון בעיות
Before contacting customer support, please refer to the following common issues and solutions. The self-diagnosis feature with a digital display can provide initial indications of problems.
| בְּעָיָה | סיבה אפשרית | פִּתָרוֹן |
|---|---|---|
| היחידה לא נדלקת | No power, remote control batteries low, unit switch off. | Check power supply, replace remote batteries, ensure indoor unit ON/OFF switch is engaged. |
| חימום/קירור לא מספקים | מסנני אוויר מלוכלכים, יחידה חיצונית חסומה, הגדרת מצב/טמפרטורה שגויה, דליפת נוזל קירור. | Clean filters, clear obstructions from outdoor unit, verify settings, contact professional for refrigerant check. |
| רעש יוצא דופן | חלקים רופפים, חסימה של מאוורר, רעש זרימת נוזל קירור (נורמלי). | Inspect for loose parts or obstructions. If noise persists or is abnormal, contact service. |
| דליפת מים מהיחידה הפנימית | Clogged drain pan/tube, improper installation. | Clean drain pan and tube. If issue persists, professional inspection is required. |
| Digital display shows error code | תקלה פנימית במערכת. | Note the error code and consult the full product manual or contact customer support for specific guidance. |
For issues not listed or if troubleshooting steps do not resolve the problem, please contact a qualified HVAC technician or ACiQ customer support.
מפרטים
Detailed technical specifications for the Goodman Mini-Split AC/Heating System E-Series (0.75 Ton, 9000 BTU).
| תְכוּנָה | עֵרֶך |
|---|---|
| שם מותג | ACiQ |
| מידע על הדגם | RXNG09AXVJU / FTXNG09AXVJU |
| BTU Capacity (Cooling) | 9,000 BTU (0.75 טון) |
| BTU Capacity (Heating) | 4,400 BTU – 13,000 BTU |
| יעילות SEER2 | 18 SEER2 |
| כרך ידtage | 208/230 Volts, 1 Phase, 60Hz |
| רמת רעש (יחידה חיצונית) | 56 dB |
| סוג התקנה | מערכת מפוצלת |
| גורם צורה | מיני-ספליט |
| חומר קירור | R 410A |
| אזור כיסוי מומלץ | עד 400 רגל מרובע |

Figure 4: Dimensional specifications and performance ratings for the Goodman Mini-Split AC/Heating System, including BTU, square footage coverage, and noise levels.
אחריות ותמיכה
For warranty information, please refer to the warranty card included with your product or visit the official ACiQ website. Warranty terms typically cover manufacturing defects and vary by component.
For technical support, service requests, or to inquire about replacement parts, please contact ACiQ customer service. Have your model number (RXNG09AXVJU / FTXNG09AXVJU) and purchase date ready when contacting support.
משאבים מקוונים: למשאבים נוספים, שאלות נפוצות ורישום מוצרים, בקרו באתר ACiQ Store on Amazon.