This manual provides essential information for the proper installation, operation, and maintenance of the Notifier FMM-1 Monitor Module. The FMM-1 is designed to monitor a circuit of normally open contact devices in a fire alarm system. It is an integral component for ensuring the safety and reliability of your fire detection system.

2. מידע בטיחות

Always adhere to local codes, standards, and regulations when installing and maintaining fire alarm equipment. Installation and servicing should only be performed by qualified personnel. Disconnect all power before servicing. Failure to follow these instructions may result in property damage, serious injury, or death.

  • ודא שהחשמל מנותק לפני התקנה או תחזוקה.
  • Follow all wiring diagrams and instructions provided by Notifier.
  • Do not operate the module outside its specified environmental limits.
  • שמור על ניקיון המודול וחופשי מאבק ופסולת.

3. תיאור המוצר ותכונותיו

The Notifier FMM-1 is a compact monitor module designed for use with Notifier intelligent fire alarm control panels. It provides a single initiating device circuit (IDC) for monitoring normally open contact devices such as manual pull stations, waterflow switches, or supervisory switches. The module communicates with the control panel using the FlashScan protocol, allowing for fast and reliable communication.

Notifier FMM-1 Monitor Module

איור 3.1: חזית view of the Notifier FMM-1 Monitor Module, showing its compact design and terminal connections.

Multiple Notifier FMM-1 Monitor Modules in original packaging

Figure 3.2: Multiple Notifier FMM-1 Monitor Modules packaged in a box, indicating new, original packaging.

4. התקנה והגדרה

The FMM-1 module is typically installed in a standard 4-inch square electrical box. It is designed for surface or flush mounting. Refer to the specific wiring diagrams provided with your Notifier fire alarm control panel for detailed connection instructions.

4.1 חיווט

Connect the module to the Signaling Line Circuit (SLC) of the fire alarm control panel and to the initiating device circuit (IDC) according to the system's design and Notifier's documentation. Ensure proper polarity and termination for all connections.

4.2 פנייה

Each FMM-1 module must be assigned a unique address on the SLC loop using the rotary switches on the module. Consult your control panel's manual for valid address ranges and programming procedures.

סרטון 4.1: אוברview of the Notifier FMM-1 Monitor Module, showcasing its physical appearance and key features. This video provides a visual guide to the module's design.

5. הוראות הפעלה

Once properly installed and addressed, the FMM-1 module operates automatically as part of the fire alarm system. It continuously monitors the connected initiating device circuit for changes in state (e.g., a pull station being activated, a waterflow switch closing). Upon detecting an alarm or supervisory condition, the module transmits this information to the fire alarm control panel, which then initiates the appropriate system response.

6. תחזוקה

Regular maintenance is crucial for the reliable operation of the FMM-1 module and the overall fire alarm system. Refer to NFPA 72 (National Fire Alarm and Signaling Code) and local authority having jurisdiction (AHJ) requirements for specific testing and maintenance schedules.

  • בדיקה שנתית: Visually inspect the module and its connections for any signs of damage, corrosion, or loose wiring.
  • בדיקה פונקציונלית: Periodically test the initiating devices connected to the FMM-1 to ensure they properly trigger an alarm or supervisory signal at the control panel.
  • ניקוי: If necessary, gently clean the module's exterior with a soft, dry cloth. Do not use abrasive cleaners or solvents.

7. פתרון תקלות

If the FMM-1 module or its associated circuit is indicating a fault condition on the fire alarm control panel, consider the following:

בְּעָיָהסיבה אפשריתפִּתָרוֹן
Module Fault/TroubleIncorrect wiring, short circuit, open circuit on IDC, incorrect addressing, module failure.Verify wiring connections and polarity. Check for shorts or opens on the IDC. Confirm correct address setting. If issues persist, replace the module.
No Response from DeviceDevice not properly connected, device failure, wiring issue on IDC.Check connections at the initiating device and the FMM-1. Test the initiating device independently. Inspect IDC wiring for breaks or damage.

For complex issues, contact a certified fire alarm technician or Notifier technical support.

8. מפרטים

  • מותג: מודיע
  • דֶגֶם: FMM 1
  • מספר חלק: FMM-1
  • UPC: 643485653585
  • יַצרָן: הודעה
  • משקל פריט: 5.6 אונקיות
  • מידות חבילה: 6.5 x 5.75 x 1.9 אינץ'
  • צֶבַע: Ivery
  • תאריך זמין ראשון: 28 באוגוסט 2015

9. אחריות ותמיכה

For warranty information and technical support, please refer to the official Notifier website or contact your authorized Notifier distributor. Keep your purchase receipt for warranty claims.

פקיד המודיעין Webאֲתַר: www.notifier.com

מסמכים קשורים - FMM 1

מִרֹאשׁview לוח אש אנלוגי NOTIFIER AFP-200 - מפרט טכני ותכונות
מפורט מעלview של לוח האש האנלוגי NOTIFIER AFP-200, הכולל את תכונותיו, קיבולת המערכת, מפרטים, מכשירים תואמים ושיטות תכנות. כולל רשימות סוכנויות ומידע על המוצר.
מִרֹאשׁview גלאי חום ליניארי מסדרת EPR ו-EPR-M של Protectowire: מפרט טכני ומדריך התקנה
מדריך מקיף לגלאי החום הלינאריים Protectowire מסדרת EPR ו-EPR-M של Notifier. מכסה את מאפייני המוצר, מפרטים טכניים, עמידות כימית, דרישות התקנה ואביזרים זמינים עבור יישומי גילוי אש תעשייתיים.
מִרֹאשׁview לוח אש חכם כתובתי NOTIFIER AFC-600 עם FlashScan®
מפרטים טכניים מפורטים ותכונות של לוח האש החכם NOTIFIER AFC-600, כולל פרוטוקול FlashScan®, טכנולוגיית חישה AWACS™™, אפשרויות תכנות, מודולי מערכת ותאימות עם מכשירים שונים.
מִרֹאשׁview מדריך חיווט Notifier SLC: מדריך התקנה של לוח בקרה חכם
מדריך חיווט מקיף עבור התקני Notifier Intelligent Control Panel SLC. מכסה התקנה, דרישות חיווט, מפרטי התקנים ואמצעי בטיחות עבור מערכות אזעקת אש, ותומך במגוון FACP של Notifier.
מִרֹאשׁview מדריך עזרה לשיווק דיגיטלי של NOTIFIER ESD: INSPIRE, בדיקה עצמית, CLSS
מדריך מקיף לשותפי ESD על מינוף אסטרטגיות שיווק דיגיטלי, מדיה חברתית ופרסום שיתופי לקידום מערכות בטיחות האש INSPIRE החדשות של NOTIFIER, גלאי בדיקה עצמית ושירותי בטיחות חיים מחוברים (CLSS).
מִרֹאשׁview לוח בקרה לגילוי אש NOTIFIER N16 - מערכת בטיחות חיים מחוברת וניתנת להרחבה
גלו את לוח בקרת גילוי האש (FACP) NOTIFIER N16 מבית Honeywell, הכולל מסך מגע בגודל 10 אינץ', קיבולת ניתנת להרחבה עבור מכשירים חכמים הניתנים לגישה, ושילוב עם שירותי בטיחות חיים מחוברים (CLSS). למדו על התכונות, המפרטים והרכיבים התואמים שלו לגילוי אש ופינוי מתקדמים.