1. הקדמה
Thank you for choosing the Westgate YM2108-T-W Vacancy and Occupancy Sensor Wall Switch. This device is designed to enhance energy efficiency and convenience by automatically controlling lighting based on room occupancy. It is suitable for various applications, including bathrooms, garages, laundry rooms, and utility areas.
2. מידע בטיחות
אַזהָרָה: To avoid fire, shock, or death; turn off power at circuit breaker or fuse box and test that power is off before wiring! This device requires a neutral wire for proper operation. If you are unsure about any part of these instructions, consult a qualified electrician.
- יש לנתק תמיד את החשמל לפני התקנה או שירות.
- ודא שכל חיבורי החיווט מאובטחים ועומדים בתקנות החשמל המקומיות.
- This product is UL Listed and Title-24 Compliant, ensuring it meets safety and energy efficiency standards.
- אין להשתמש עם עומסים שחורגים מהדירוגים שצוינו.
3. המוצר נגמרview
The Westgate YM2108-T-W is a versatile wall switch that can function as either a vacancy sensor or an occupancy sensor, providing flexible lighting control. Its decorative style blends seamlessly with most interiors.

איור 1: חזית view of the Westgate YM2108-T-W Vacancy and Occupancy Sensor Wall Switch. The switch is white with a clear sensor lens at the top and a solid white lower section, mounted within a standard white wall plate.
תכונות עיקריות:
- Automatically turns lights on or off based on motion detection.
- Functions as both an occupancy (auto-on/auto-off) and vacancy (manual-on/auto-off) sensor.
- Replaces standard single-pole or 3-way switches.
- Adjustable time delay from 1 minute to 30 minutes.
- Adjustable light level sensitivity.
- Compatible with incandescent, fluorescent, low voltage, electronic, and magnetic loads, including bathroom fans.
- UL Listed and Title-24 Compliant.
4. התקנה והתקנה
Before beginning installation, ensure power is OFF at the circuit breaker. This sensor requires a neutral wire connection. If your existing switch box does not have a neutral wire, consult a qualified electrician.
- כבה את המתח: אתר את מפסק החשמל ששולט במתג שאתה מחליף וכבה אותו. ודא שהחשמל כבוי באמצעות מכשיר עוצמהtagבודק e.
- הסר את המתג הישן: הסר בזהירות את לוחית הקיר הקיימת ופתח את המתג הישן מקופסת הקיר. נתק את החוטים מהמתג הישן, תוך שים לב לחיבורים שלהם.
- זיהוי חוטים: Identify the Line (hot), Load, Neutral, and Ground wires in the wall box. The Westgate YM2108-T-W typically has five wires: Line, Load, Neutral, Ground, and a Traveler wire for 3-way applications.
- חיבורי חוטים: Connect the wires from the wall box to the corresponding wires on the Westgate sensor using wire nuts.
- חבר את קַו wire to the sensor's Line wire.
- חבר את לִטעוֹן wire to the sensor's Load wire.
- חבר את נֵטרָלִי wire to the sensor's Neutral wire.
- חבר את טָחוּן wire to the sensor's Ground wire.
- עבור יישומים תלת-כיווניים, חברו את נוֹסֵעַ wire to the sensor's Traveler wire and to the corresponding traveler wire on the other 3-way switch. For single-pole applications, cap off the traveler wire.
- חיישן הרכבה: Carefully push the wired sensor into the wall box and secure it with the provided screws.
- התקן לוחית קיר: חבר את לוחית הקיר החדשה.
- החזר כוח: הפעל מחדש את החשמל במפסק החשמל.
5. הוראות הפעלה
The Westgate YM2108-T-W sensor offers flexible operation modes and adjustable settings.
מצבי הפעלה:
- Occupancy Mode (Auto-ON/Auto-OFF): In this mode, the lights will automatically turn ON when motion is detected and turn OFF after the set time delay when no motion is detected.
- Vacancy Mode (Manual-ON/Auto-OFF): In this mode, the lights must be manually turned ON by pressing the switch. They will then automatically turn OFF after the set time delay when no motion is detected. This mode is Title 24 compliant.
The mode can typically be selected via a small switch or setting on the device itself, often accessible by removing the wall plate or a small cover.
הגדרות מתכווננות:
- עיכוב זמן: Adjust the time the lights remain ON after the last detected motion. This can typically be set from 1 minute to 30 minutes. Locate the adjustment dial or switch on the sensor and set it to your desired duration.
- Light Level Sensitivity (Photocell): This setting determines at what ambient light level the sensor will allow the lights to turn on (primarily in Occupancy mode). If the room is already bright enough, the sensor can be set to prevent lights from turning on. Adjust this setting to suit your environment.
6. תחזוקה
The Westgate YM2108-T-W sensor is designed for minimal maintenance. To ensure optimal performance and longevity:
- ניקוי: Periodically wipe the sensor lens and outer surface with a soft, dry cloth. Do not use abrasive cleaners, solvents, or excessive moisture, as these can damage the device.
- בְּדִיקָה: Occasionally inspect the wall plate and sensor for any signs of damage or loose connections.
No user-serviceable parts are inside. Refer all servicing to qualified personnel.
7. פתרון תקלות
If you experience issues with your Westgate YM2108-T-W sensor, refer to the following common problems and solutions:
| בְּעָיָה | סיבה אפשרית | פִּתָרוֹן |
|---|---|---|
| האורות לא נדלקים אוטומטית. |
|
|
| האורות לא כבים. |
|
|
| Sensor is unresponsive. |
|
|
8. מפרטים
| תְכוּנָה | פְּרָט |
|---|---|
| מותג | ווסטגייט |
| מספר דגם | YM2108-T-W |
| יַצרָן | Westgate Manufaturing |
| מקור כוח | חשמלי עם כבלים |
| סוג הרכבה | מתקן קיר |
| צֶבַע | לָבָן |
| מידות חבילה | 4.7 x 2.9 x 2.3 אינץ' |
| משקל פריט | 5.6 אונקיות |
| תיאור הסוללה | סוללה לא כלולה |
| הַתאָמָה | UL Listed, Title-24 Compliant |
9. אחריות ותמיכה
For warranty information and technical support regarding your Westgate YM2108-T-W Vacancy and Occupancy Sensor Wall Switch, please contact Westgate Manufaturing directly. Retain your proof of purchase for warranty claims.