The Riello IDG 1200 is a compact and reliable Uninterruptible Power Supply (UPS) designed to protect your electronic devices from power outages and fluctuations. It provides a stable power source, ensuring continuous operation and safeguarding your equipment from potential damage. This manual provides essential information for the proper installation, operation, and maintenance of your Riello IDG 1200 UPS.

This image shows the Riello IDG 1200 UPS unit from a front-side angle. The device is black, compact, and designed for vertical placement. The front panel features the 'Riello iDialog UPS' logo. Ventilation grilles are visible on the side.
2. התקנה
2.1 פירוק
Carefully remove the UPS from its packaging. Inspect the unit for any signs of damage that may have occurred during transit. Retain the packaging for future transport or storage.
2.2 מיקום
Due to its compact form factor, the Riello IDG 1200 can be positioned almost anywhere. Ensure the chosen location is:
- Well-ventilated, allowing for proper heat dissipation.
- Away from direct sunlight, heat sources, and excessive humidity.
- על משטח יציב ושטוח.
2.3 חיבור UPS
- חבר את כבל החשמל של מערכת ה-UPS לשקע קיר מוארק.
- Connect your computer, monitor, and other critical devices to the output sockets on the rear of the UPS. Ensure the total power consumption of connected devices does not exceed the UPS's capacity (720W).
- For advanced monitoring and management, connect the UPS to your computer via the appropriate communication port (e.g., USB, if available).
2.4 התקנת תוכנה (אופציונלי)
The Riello IDG 1200 is compatible with various operating systems, including Windows Vista, 2003, XP, 2000, Me, 98, Linux, Mac OSX, and Sun Solaris. For enhanced control and monitoring features, install the Riello UPS management software on your computer. Refer to the software's documentation for installation instructions.
3. הוראות הפעלה
3.1 הפעלת UPS
Press and hold the power button on the front panel for a few seconds until you hear a beep and the indicators light up. The UPS will perform a self-test and then enter normal operating mode.
3.2 כיבוי ה-UPS
To turn off the UPS, press and hold the power button again until the indicators turn off and you hear a final beep. Ensure all connected devices are properly shut down before turning off the UPS.
3.3 הפעלה מחדש אוטומטית
The Riello IDG 1200 features an automatic restart function. After a power outage and when utility power is restored, the UPS will automatically restart and resume providing power to connected devices, provided the battery has sufficient charge.
3.4 מצב סוללה
When utility power fails, the UPS will automatically switch to battery mode, providing backup power to connected devices. An audible alarm may sound to indicate that the UPS is operating on battery power. The alarm will typically become more frequent as the battery charge depletes.
4. תחזוקה
4.1 טיפול בסוללה
The UPS contains sealed lead-acid batteries. To maximize battery life:
- Keep the UPS connected to a power outlet to ensure the batteries remain fully charged.
- הימנעו מאחסון ה-UPS בטמפרטורות קיצוניות.
- Perform a battery self-test periodically (if supported by the management software) to assess battery health.
- The typical battery recharge time is approximately 8 hours.
4.2 ניקוי
Clean the exterior of the UPS with a soft, dry cloth. Do not use liquid or aerosol cleaners. Ensure ventilation openings are free from dust and obstructions.
4.3 החלפת סוללה
Battery replacement should only be performed by qualified service personnel. Refer to the manufacturer's guidelines for battery replacement procedures and compatible battery types.
5. פתרון תקלות
This section provides solutions to common issues you might encounter with your Riello IDG 1200 UPS. If the problem persists after attempting these solutions, please contact customer support.
| בְּעָיָה | סיבה אפשרית | פִּתָרוֹן |
|---|---|---|
| ה-UPS לא נדלק. | אין מתח קלט; סוללה ריקה לחלוטין. | Ensure the power cord is securely plugged into a live wall outlet. Allow the UPS to charge for at least 8 hours before attempting to turn it on. |
| ה-UPS מצפצף ברציפות במצב רגיל. | מצב עומס יתר. | Disconnect non-essential equipment from the UPS until the alarm stops. Ensure total load does not exceed 720W. |
| UPS עובר למצב סוללה לעתים קרובות. | חשמל לא יציב; הגדרת הרגישות גבוהה מדי. | Check your utility power supply. If using management software, adjust the UPS sensitivity setting (refer to software manual). |
| זמן גיבוי קצר. | Battery is old or not fully charged; Overload. | Allow the UPS to charge for 8 hours. Reduce the connected load. Consider battery replacement if the battery is old. |
6. מפרטים
| תכונה | מִפרָט |
|---|---|
| מותג | רילו |
| מספר דגם | IDG 1200 |
| סִדרָה | iDialog |
| קיבולת הספק פלט | 1200 VA / 720 W |
| כרך ידtage | 1200 Volts (Input/Output nominal) |
| צֶבַע | שָׁחוֹר |
| חוֹמֶר | מַתֶכֶת |
| מידות המוצר | 9.3 x 31 x 27 ס"מ |
| משקל פריט | 3.7 קילוגרם |
| סוג סוללה | Lead Acid, AGM |
| זמן טעינת סוללה | 8 שעות |
| גורם צורה | קוֹמפָּקטִי |
| תאריך זמין ראשון | 3 בינואר 2012 |
7. מה בקופסה
The Riello IDG 1200 package typically includes:
- Riello IDG 1200 UPS Unit
- כבלי חשמל
- מדריך למשתמש (מסמך זה)
- Communication Cable (e.g., USB cable for software connection)
8. אחריות ותמיכה
For warranty information, technical support, or service inquiries, please refer to the warranty card included with your product or visit the official Riello webאתר. שמור את קבלת הרכישה כהוכחת קנייה לתביעות אחריות.
Riello Official Webאֲתַר: www.riello-ups.com