Leviton 8215-PLC

Leviton 8215-PLC Hospital Grade Plug Instruction Manual

Model: 8215-PLC

מָבוֹא

The Leviton 8215-PLC is a 15 Amp, 125 Volt, NEMA 5-15P, 2-pole, 3-wire, straight blade grounding plug designed for hospital grade applications. This transparent plug features a power indication LED, allowing for visual confirmation of power presence. Constructed with a super tough nylon body and solid brass blades and contacts, it offers durability, superior conductivity, and resistance to impact, abrasion, and chemicals.

Leviton 8215-PLC Hospital Grade Plug

Image: The Leviton 8215-PLC Hospital Grade Plug, transparent with a green power indicator.

מידע בטיחות

אַזהָרָה: To avoid fire, shock, or death, always turn off power at the circuit breaker or fuse box before wiring. This device must be installed in accordance with all national and local electrical codes. If you are unsure about any part of these instructions, consult a qualified electrician.

התקנה והתקנה

This section provides instructions for properly wiring the Leviton 8215-PLC plug to a power cord. Ensure the power cord is appropriate for the intended application and current rating.

כלים נדרשים:

הוראות חיווט:

  1. Prepare the Cord: Carefully strip the outer jacket of your power cord to expose approximately 1.5 to 2 inches of the insulated wires (typically black, white, and green/bare copper). Then, strip about 1/2 inch of insulation from the ends of the black (hot), white (neutral), and green/bare copper (ground) wires.
  2. לפרק את התקע: Unscrew the assembly screws on the plug body to separate the front and back sections. Slide the back cover and cord clamp components onto the power cord in the correct orientation.
  3. חבר את החוטים: The Leviton 8215-PLC features internal wiring chambers designed to isolate individual conductors. Connect the wires to the appropriate terminals:
    • Green/Bare Copper Wire: התחבר ל יָרוֹק (grounding) screw terminal.
    • חוט לבן: התחבר ל כֶּסֶף (neutral) screw terminal.
    • חוט שחור: התחבר ל פְּלִיז (hot) screw terminal.
    Ensure all wire strands are securely under the screw heads and tightened firmly. Trim any excess wire strands to prevent short circuits.
  4. Secure the Cord Clamp: Position the cord clamp around the power cord and tighten the screws to provide a secure grip without damaging the cord's outer jacket. This prevents strain on the wire connections.
  5. חברו מחדש את התקע: Carefully align the front and back sections of the plug, ensuring no wires are pinched. Securely fasten the assembly screws.
Internal wiring chambers of the plug

תמונה: תקריב view of the internal wiring chambers, showing isolated conductors and screw terminals.

Plug with cord clamp securing a cable

Image: The plug's cord clamp mechanism, designed to secure the power cord and prevent strain.

הוראות הפעלה

Once properly wired, the Leviton 8215-PLC plug is ready for use.

  1. התחבר לכוח: Insert the plug firmly into a compatible 125V, 15A NEMA 5-15R receptacle.
  2. Verify Power Indication: The long-life LED bulb on the transparent body of the plug will illuminate green when power is present at the device. This provides a quick visual confirmation that the circuit is live and the plug is receiving power.
  3. מתנתק: To disconnect, grasp the plug body firmly and pull it straight out from the receptacle. Do not pull by the cord.

תַחזוּקָה

Regular inspection and basic maintenance can help ensure the longevity and safe operation of your Leviton 8215-PLC plug.

פתרון בעיות

If you encounter issues with your Leviton 8215-PLC plug, refer to the following troubleshooting steps:

מפרטים

מספר דגם 8215-PLC
Ampלמחוק 15 Amps
כרך ידtage 125 וולט
תצורת NEMA 5-15P
מוטות/חוטים הארקה 2 קוטבים, 3 חוטים
ציון מוצר כיתה בית חולים
חוֹמֶר Super Tough Nylon (Body), Thermoplastic (Back Cover)
צֶבַע שָׁקוּף
חיווי כוח נורת לד
אישורים UL 498, CSA C22.2, NOM 057
משקל פריט 0.01 אונקיות
מידות המוצר 9.38 x 7.13 x 9 אינץ'

מידע על אחריות

This Leviton product is covered by the manufacturer's limited lifetime warranty. For detailed information regarding warranty terms, conditions, and registration, please refer to the official Leviton website or contact Leviton customer service directly. Keep your proof of purchase for warranty claims.

תמיכת לקוחות

For technical assistance, product inquiries, or further support, please visit the official Leviton website or contact their customer service department. Contact information can typically be found on the Leviton webאתר או אריזת מוצר.

לויטון Webאֲתַר: www.leviton.com

מסמכים קשורים - 8215-PLC

מִרֹאשׁview מדריך בחירת מתגים מסחריים ותעשייתיים של Leviton
מדריך מקיף לבחירה מבית Leviton המפרט מתגים מסחריים ותעשייתיים, כולל מתגים מסוג Toggle, Decora Plus, Lev-lok, מתגים אנטי-מיקרוביאליים ומתגים מיוחדים עם פרטי יישום ותרשימי חיווט.
מִרֹאשׁview מדריך התקנה ובדיקה של שקע GFCI של Leviton
מדריך מקיף להתקנה ובדיקה של שקע Leviton SmartLock Pro GFCI, כולל הוראות חיווט, אמצעי בטיחות וטיפים לפתרון בעיות.
מִרֹאשׁview Leviton EV40P EV סדרה 40 AMP מדריך התקנה של מטען פלאגין
מדריך התקנה עבור Leviton EV40P EV סדרה 40 AMP מטען לרכב חשמלי נטען. כולל אזהרות בטיחות, מפרטים, שלבי התקנה, נהלי הפעלה, שימוש בכרטיס RFID, הודעות שגיאה, תחזוקה ומידע על אחריות.
מִרֹאשׁview מדריך התקנה ותפעול של שקע GFCI של Leviton עם יציאות USB
מדריך מקיף להתקנה ותפעול של שקעי GFCI של Leviton עם יציאות USB, כולל הוראות חיווט, אזהרות בטיחות, נהלי בדיקה ומידע על אחריות.
מִרֹאשׁview התקנה ובדיקה של שקע Leviton Smart GFCI: מדריך מקיף
הוראות שלב אחר שלב להתקנה ובדיקה של שקעי Leviton Smart GFCI (דגמים D2GF1, D2GF2). למד על פונקציונליות GFCI, חיווט, פתרון בעיות ואמצעי בטיחות.
מִרֹאשׁview הוראות התקנה של מארז מרכז העומס של לויטון
הוראות התקנה מפורטות עבור מארזי מרכז עומסים של Leviton, דגמים LP2xx, LP3xx, LP4xx ו-LP6xx. מכסה בטיחות, הסרת נוקאאוט, הרכבה, חיווט, התקנת מפסק זרם והרכבת כיסוי.