Glucoracy G-425-2

מדריך למשתמש לערכת ניטור גלוקוז בדם Glucoracy G-425-2

דגם: G-425-2

מָבוֹא

This manual provides detailed instructions for the safe and effective use of your Glucoracy G-425-2 Blood Glucose Monitor Kit. Please read all instructions carefully before use to ensure accurate results and proper operation. This kit is designed for self-testing blood glucose levels at home.

תוכן ערכה

Your Glucoracy G-425-2 Blood Glucose Monitor Kit includes the following components:

Glucoracy G-425-2 Blood Glucose Monitor Kit contents including glucometer, lancing device, test strips, and lancets.

Image: Complete Glucoracy G-425-2 Blood Glucose Monitor Kit components.

הגדרה

1. התקן סוללות

The Glucoracy G-425-2 meter requires 2 AAA batteries (not included). Open the battery compartment on the back of the meter and insert the batteries, ensuring correct polarity. Close the compartment securely.

2. Assemble Lancing Device

  1. Unscrew the cap from the lancing device.
  2. הכנס לנסט חדש וסטרילי בחוזקה למחזיק הלנסט.
  3. סובב את מכסה המגן מהלנסט.
  4. החזר את מכסה מכשיר הדקירה למקומו.
  5. Adjust the penetration depth by rotating the cap. Levels 1-2 are for tender skin, 3 for general, and 4-5 for thick skin.
  6. Pull back the cocking control until it clicks, indicating the device is ready.
Image showing the lancing device with adjustable depth settings from 1 to 5, indicating suitability for different skin types.

Image: Lancing device with adjustable depth settings.

הוראות הפעלה

Before Testing: Important Reminders

Infographic showing factors affecting blood glucose test accuracy and their solutions, such as clean skin, sufficient blood, proper strip storage, and using fingertip.

Image: Factors affecting test accuracy and solutions.

ביצוע בדיקת גלוקוז בדם

  1. Prepare Hands: Wash your hands with soap and warm water, then dry them completely.
  2. הכנס רצועת בדיקה: Remove a test strip from its vial and immediately close the vial lid. Insert the test strip into the meter. The meter will turn on automatically.
  3. השג Blood Sampעל: Place the assembled lancing device firmly against the side of your fingertip and press the release button. Gently squeeze your finger until a small drop of blood forms. Wipe away the first drop of blood with a clean tissue, then gently squeeze again to get a second drop.
  4. למרוח דם: Touch the tip of the test strip to the blood drop. The blood will be drawn into the strip automatically. Do not apply blood to the top of the strip.
  5. קרא תוצאות: The meter will display your blood glucose result in 5 seconds.
  6. Eject Strip and Lancet: Use the one-button push ejection feature to safely dispose of the used test strip and lancet.
Image illustrating the 8 simple steps for blood glucose testing, from washing hands to ejecting the strip and lancet.

Image: 8 Simple steps for blood glucose testing.

Memory Tracking

The Glucoracy G-425-2 glucometer can store up to 500 blood sugar results, helping you monitor your glucose status over time. To access memory mode, refer to the specific instructions in your meter's user manual. The meter also allows for testing at different times relative to meals:

Image showing the Glucoracy glucometer display with a reading of 98 mg/dL, and icons indicating different testing times like fasting, before meal, after meal, and before sleep.

Image: Glucometer display and suggested testing times.

תַחזוּקָה

Test Strip Storage

Cleaning the Meter and Lancing Device

Wipe the exterior of the meter and lancing device with a soft, damp cloth. Do not immerse the devices in water or use harsh cleaning agents.

פתרון בעיות

If you encounter any issues, refer to the table below for common error messages and their solutions. If the problem persists or an unfamiliar error message appears, please contact Glucoracy customer service.

הוֹדָעָהמה זה אומרפְּעוּלָה
LoBlood glucose level is lower than 20 mg/dL.Consult with your healthcare professional immediately.
HiBlood glucose level is higher than 600 mg/dL.פנה לעזרה רפואית מיידית.
CTLMeter is ready to test control solution.Place a drop of control solution onto the test well of the test strip.
Ebעוצמת הסוללה נמוכה.החלף את הסוללות.
אירופהמוכנס רצועת בדיקה משומשת.Use a new strip and re-test.
EFIndicates you may have removed the strip prematurely after applying blood to the absorbent hole.Try again with a new strip, ensuring sufficient blood sample and proper application.
EEבעיה במונה.Re-test with a new test strip. If the problem is still unresolved, please contact customer care.
א.תEnvironmental temperature is lower than 50°F or higher than 104°F.Test at an environmental temperature within 50°F–104°F (10°C–40°C) operation range.
Table showing various error messages like Lo, Hi, E-b, E-U, E-F, E-E, E-t, their meanings, and recommended actions for the Glucoracy blood glucose monitor.

Image: Common error messages and troubleshooting steps.

מפרטים

מידע חשוב

This device is intended for self-testing and monitoring of blood glucose levels. It is not intended for the diagnosis of diabetes. Always consult with a healthcare professional for diagnosis and treatment decisions.

אינדיקציות: For individuals managing diabetes.

תמיכת לקוחות

For any questions, concerns, or technical assistance, please contact Glucoracy customer service. Refer to the packaging or the official Glucoracy webהאתר לפרטי יצירת קשר.

You can also visit the official Glucoracy store for more information: Glucoracy Store