מָבוֹא
This manual provides essential information for the safe and efficient operation of your APC Back-UPS Slim BV400XU. This Uninterruptible Power Supply (UPS) is designed to provide advanced power protection for digital signage, retail POS systems, and other IoT/Edge applications in various environments, including those with harsh conditions. It ensures consistent and reliable connectivity by protecting against power spikes, surges, and outages.
מידע בטיחות חשוב
Please read and understand these instructions carefully before installing, operating, servicing, or maintaining this equipment. Failure to follow these instructions can result in equipment damage, property damage, or serious injury.
- סַכָּנָה: Hazard of electric shock, explosion, or arc flash. Batteries may cause chemical hazard, electrical shock, and energy hazard. Refer to user manual for details on maintenance, handling, and disposal requirements for batteries. Failure to follow these instructions will result in death or serious injury.
- הוֹדָעָה: Equipment operation hazard. The output of this device is not purely sinusoidal. It has a normal total voltagעיוות הרמוני של 45 אחוזים, כאשר הערך הנומינלי של הנפח הבודד הגדול ביותרtage harmonic of 40 percent. Failure to follow these instructions can result in equipment damage.
- UPS זה מיועד לשימוש פנימי בלבד.
- אין להפעיל את ה-UPS הזה באור שמש ישיר, במגע עם נוזלים, או במקום שיש אבק או לחות מוגזמת.
- Ensure proper ventilation around the UPS.
- Connect the UPS power cable directly to a wall outlet, not to a surge protector or extension cord.
המוצר נגמרview
The APC Back-UPS Slim BV400XU is a compact and robust Uninterruptible Power Supply designed for environments requiring reliable power backup and surge protection. Its slim profile and flexible mounting options make it suitable for various applications.
תכונות עיקריות:
- 400VA / 220W capacity for essential equipment.
- 3 battery backup & surge protector outlets (NEMA 5-15R).
- Flexible mounting options: VESA mount, Din-Rail mount, and Wall-mount.
- Slim design for space-saving installations.
- High temperature threshold (32-122°F / 0-50°C) for harsh environments.
- Energy-Star Certified for energy efficiency.
רכיבים:

איור 1: לוח אחורי View. This image displays the rear panel of the APC Back-UPS Slim BV400XU, highlighting the three NEMA 5-15R battery backup and surge protector outlets, the circuit breaker, and the input power cord connection. Important safety and operational notices are also visible.

Figure 2: Communication Ports and Outlets. This diagram illustrates the various communication ports and power outlets on the APC Back-UPS. It points out the On-line LED, On-Battery LED, Alert LED, Data Port, and the three NEMA 5-15 outlets for surge and battery backup, along with the circuit breaker.
התקנה והתקנה
Follow these steps to properly set up your APC Back-UPS Slim BV400XU.
פריקת אריזה:
- Carefully unpack the UPS and inspect it for any shipping damage.
- Retain the packaging materials for future use or recycling.
אפשרויות הרכבה:
The BV400XU offers versatile mounting capabilities to suit various installation environments.
- VESA Mount: Attach the UPS to the back of a VESA-compatible display or monitor arm.
- Din-Rail Mount: Secure the UPS to a standard Din-Rail for industrial applications.
- קיר קיר: Directly mount the UPS to a wall using appropriate hardware.

Figure 3: VESA Mount Example. This image shows the APC Back-UPS Slim BV400XU discreetly mounted behind a computer monitor, which is attached to an articulating arm. This demonstrates the VESA mounting capability, ideal for saving space in workstations or digital signage setups.

Figure 4: Retail POS Stand Mount Example. The image illustrates the APC Back-UPS Slim BV400XU integrated into a retail point-of-sale (POS) system stand. This setup highlights its use in commercial environments where space is limited and reliable power is crucial for transaction processing.

Figure 5: Detailed Stand Mount. קרוב יותר view of the APC Back-UPS Slim BV400XU mounted on a stand, emphasizing the VESA mounting plate connection. This provides a clearer perspective on how the unit attaches securely to various fixtures.
ציוד חיבור:
- Connect the UPS to a grounded 120V AC outlet using the provided 5-foot input power cord (NEMA 5-15P).
- Plug your critical equipment (e.g., digital signage, POS terminal, router) into the three NEMA 5-15R outlets on the rear of the UPS. These outlets provide both battery backup and surge protection.
- ודא שכל החיבורים מאובטחים.
הפעלת ה-UPS
Once installed, operating the BV400XU is straightforward.
הפעלה/כיבוי:
- To power on the UPS, press the power button located on the front panel.
- To power off the UPS, press and hold the power button until the unit shuts down.
מחווני LED:
הפאנל הקדמי כולל מספר מחווני LED המספקים מידע על המצב:
- On-line LED: מציין שמערכת ה-UPS פועלת על מתח חשמל מהרשת.
- On-Battery LED: Indicates the UPS is operating on battery power (during a power outagה).
- נורית התראה: Illuminates to indicate a fault or warning condition. Refer to the troubleshooting section for details.
אזעקות קוליות:
The UPS uses audible alarms to signal various conditions:
- מצב סוללה: Beeps every 30 seconds when operating on battery power.
- סוללה חלשה: Beeps rapidly when battery power is critically low.
- לְהַעֲמִיס יוֹתֵר מִדַי: Continuous tone indicates an overload condition.
- תַקָלָה: Continuous tone indicates a UPS fault.
תַחזוּקָה
תחזוקה שוטפת מבטיחה את אורך החיים והביצועים האופטימליים של מערכת ה-UPS שלכם.
החלפת סוללה:
The internal battery is a sealed lead-acid type and is not user-replaceable. Contact APC support for battery service or replacement. Attempting to replace the battery yourself can void the warranty and pose a safety risk.
ניקוי:
- Clean the exterior of the UPS with a soft, dry cloth.
- אין להשתמש בחומרי ניקוי נוזליים או אירוסולים.
- יש לשמור על פתחי האוורור נקיים מאבק ופסולת כדי להבטיח זרימת אוויר תקינה.
פתרון בעיות
This section provides solutions to common issues you might encounter with your APC Back-UPS Slim BV400XU.
| בְּעָיָה | סיבה אפשרית | פִּתָרוֹן |
|---|---|---|
| ה-UPS לא נדלק. | No utility power; Battery not connected; UPS fault. | Verify utility power; Ensure UPS is plugged into a live outlet; Contact support if fault persists. |
| ה-UPS מצפצף ברציפות. | Overload condition; UPS fault. | Reduce connected load; Check circuit breaker; Contact support. |
| UPS operates on battery frequently. | Unstable utility power; High/low voltage. | This is normal operation if utility power is fluctuating. If frequent, consult an electrician. |
| זמן פעולה קצר של סוללה. | Battery near end of life; Overload; Battery not fully charged. | Allow battery to charge for 24 hours; Reduce load; Contact support for battery replacement. |
מפרטים
Detailed technical specifications for the APC Back-UPS Slim BV400XU.
| מִפרָט | עֵרֶך |
|---|---|
| מספר דגם | BV400XU |
| קיבולת (VA/וואט) | 400VA / 220W |
| קלט כרךtage | 120 וולט |
| פלט כרךtage | 120 וולט |
| מספר אאוטלטים | 3 (NEMA 5-15R, Battery Backup & Surge Protection) |
| כבל חשמל קלט | 5' (NEMA 5-15P) |
| הרכב תא הסוללה | חומצת עופרת אטומה |
| Typical Runtime | 8 hours (at low load) |
| טמפרטורת הפעלה | 0 - 50 מעלות צלזיוס (32 - 122 מעלות פרנהייט) |
| מידות (H x W x D) | 10.24 x 4.72 x 12.48 אינץ' |
| הסמכות | אנרג'י סטאר |
אַחֲרָיוּת
The APC Back-UPS Slim BV400XU comes with a אחריות יצרן לשנה. Please retain your proof of purchase for warranty claims. For full terms and conditions, refer to the official APC webאתר או צור קשר עם תמיכת הלקוחות.
תמיכת לקוחות
For technical assistance, troubleshooting, or warranty inquiries, please contact APC customer support. You can find contact information and additional resources on the official APC webאֲתַר:
Please have your model number (BV400XU) and serial number ready when contacting support.
סרטון מוצר
צפו בסרטון המוצר הרשמי הזה לקבלת מידע נוסףview of the APC Back-UPS Slim BV400XU's features and applications.
Video: Industrial Use - Flexible Mounting, Low Profile. This video demonstrates the APC Back-UPS Slim BV400XU's suitability for commercial and industrial environments, highlighting its flexible mounting options and low-profile design. It showcases how the UPS addresses common limitations in deploying power backup solutions in such settings.