1. המוצר נגמרview
The BELL 5874-5S is a 1-gang complete flip cover kit designed for outdoor electrical installations. It includes a self-test GFCI (Ground Fault Circuit Interrupter) receptacle, a weatherproof box, and a flip cover, all in a gray finish. This unit provides enhanced safety by protecting against electrical shocks in wet or damp מיקומים.
תכונות עיקריות:
- Self-test GFCI for continuous safety monitoring.
- Rugged die-cast construction for durability.
- State-of-the-art powder coat finish for maximum weatherability and scratch resistance.
- Self-closing lids ensure weatherproof protection when the receptacle is not in use.
- Includes gasket and mounting hardware for easy installation.

איור 1: חזית view of the Hubbell 5874-5S Weatherproof Box with the cover open, revealing the integrated GFCI receptacle.
2. מידע בטיחות
אַזהָרָה: To avoid fire, shock, or death; turn off power at circuit breaker or fuse box and test that power is off before wiring! This device must be installed by a qualified electrician in accordance with all national and local electrical codes.
- יש לנתק תמיד את החשמל לפני התקנה או שירות.
- אין להשתמש אם המוצר נראה פגום.
- ודא שכל החיבורים מאובטחים ומבודדים כראוי.
- This product is designed for outdoor use and must be installed in a location protected from direct water spray, as per local codes.
- אזהרה לפי הצעה 65: מוצר זה עשוי להכיל כימיקלים הידועים למדינת קליפורניה כגורמים לסרטן ומומים מולדים או נזקים אחרים למערכת הרבייה.
3. התקנה והתקנה
- הכן את אתר ההתקנה: Ensure the electrical box or mounting surface is clean, dry, and free of debris. Turn off power at the main circuit breaker.
- Mount the Weatherproof Box: Position the weatherproof box over the existing electrical box or mounting surface. Use the included mounting hardware to securely fasten the box. Ensure the gasket is properly seated between the box and the mounting surface to maintain a watertight seal.
- Wire the GFCI Receptacle: Connect the electrical wires to the GFCI receptacle terminals. Refer to the wiring diagram on the GFCI unit itself. Typically, the "LINE" terminals connect to the incoming power from the circuit breaker, and the "LOAD" terminals (if used) connect to downstream receptacles or devices that also require GFCI protection. Ensure proper polarity (hot, neutral, ground).

איור 2: אחורי view of the GFCI receptacle, indicating LINE and LOAD terminals for wiring.
- Install the GFCI into the Box: Carefully fold the wires and insert the GFCI receptacle into the weatherproof box opening. Secure it with the provided screws.
- סגור את מכסה ההנעה: Ensure the self-closing flip cover operates smoothly and provides a tight seal when closed.
- החזר כוח: Turn on power at the main circuit breaker.
4. הוראות הפעלה
The integrated GFCI receptacle is designed for user safety. It continuously monitors the electrical current and will trip (shut off power) if it detects a ground fault, preventing electrical shock.
GFCI Self-Test Function:
This GFCI features an automatic self-test function. It periodically performs an internal test to ensure it is functioning correctly. If the GFCI fails the self-test, the indicator light will turn RED, and the unit will trip, indicating it needs replacement.
Manual Test and Reset:
- לחצן TEST: Press the "TEST" button (usually black or red) to manually trip the GFCI. This should cause the power to the receptacle to shut off.
- כפתור אתחול: After testing or if the GFCI has tripped, press the "RESET" button (usually red or white) to restore power. If the GFCI does not reset, or trips immediately, there may be a ground fault or wiring issue that needs to be addressed.
Self-Closing Lids:
The flip cover features self-closing lids that automatically close when a plug is removed. This ensures continuous weatherproof protection for the receptacle when it is not in use.
5. תחזוקה
- ניקוי רגיל: Periodically clean the exterior of the weatherproof box with a damp בַּד. אין להשתמש בחומרי ניקוי שוחקים או ממסים.
- בדיקת GFCI חודשית: It is recommended to manually test the GFCI monthly by pressing the "TEST" button and then the "RESET" button. This verifies its proper operation.
- בדוק לאיתור נזק: Regularly inspect the box and cover for any signs of physical damage, cracks, or wear. Replace the unit if any damage is observed.
6. פתרון תקלות
- GFCI Will Not Reset:
סיבה אפשרית: A ground fault exists in the circuit or connected appliance. The GFCI is faulty. Power is off to the circuit.
פִּתָרוֹן: Unplug all appliances from the GFCI and any downstream outlets. Try to reset. If it resets, plug appliances back in one by one to identify the faulty appliance. If it still won't reset, check the circuit breaker. If the breaker is on and no appliances are connected, the GFCI may be faulty and needs replacement. Observe the indicator light: if it's RED, replacement is necessary.
- אין חשמל לשקע:
סיבה אפשרית: GFCI is tripped. Circuit breaker is off. Loose wiring connection.
פִּתָרוֹן: Press the "RESET" button on the GFCI. Check the circuit breaker in your electrical panel. Ensure all wiring connections are secure (only perform if power is off and you are qualified).
7. מפרטים
| תכונה | פְּרָט |
|---|---|
| סוג מוצר | 1-Gang, Complete Flip Cover Kit, Self Test GFCI, Flip Cover, Box, Receptacle |
| מספר דגם | 5874-5S |
| מותג | פַּעֲמוֹן |
| יַצרָן | האבבל |
| צֶבַע | אָפוֹר |
| חוֹמֶר | יציקת מתכת |
| מידות המוצר | 3.14 x 7 x 8.5 אינץ' |
| משקל פריט | 5.44 אונקיות |
| מכשירים תואמים | All (standard electrical plugs) |
| Power Plug סוג | Type A - 2 pin (North American) |

Figure 3: Dimensions of the GFCI receptacle component.
8. אחריות ותמיכה
This BELL product is manufactured by Hubbell and is designed for durability and performance. For specific warranty information or technical support, please refer to the documentation included with your purchase or visit the official BELL/Hubbell webאֲתַר. שמור את קבלה הרכישה שלך לתביעות אחריות.
For further assistance, you may contact BELL customer service through their official channels.