תאורת פרוגרס P2501-09

Progress Lighting AirPro Collection Builder 52" 5-Blade Ceiling Fan User Manual

דגם: P2501-09

מָבוֹא

This manual provides comprehensive instructions for the safe installation, operation, and maintenance of your Progress Lighting AirPro Collection Builder 52" 5-Blade Ceiling Fan. Please read this manual thoroughly before beginning installation or operation to ensure proper function and safety.

The Progress Lighting AirPro Collection Builder 52" 5-Blade Ceiling Fan features a Nickel finish and is designed for indoor use. It is Energy Star Compliant and energy efficient, offering both functionality and modern aesthetics for living rooms and home offices.

מידע בטיחות חשוב

Always follow basic safety precautions when installing and operating electrical appliances. This includes, but is not limited to:

  • ודא שהחשמל מנותק במפסק החשמל לפני התקנה או שירות.
  • כל החיווט חייב להיות בהתאם לתקנות החשמל הלאומיות והמקומיות.
  • התייעץ עם חשמלאי מוסמך אם אינך בטוח לגבי נהלי החיווט.
  • The fan must be mounted with a minimum of 7 feet (2.1 meters) clearance from the floor to the trailing edge of the blades.
  • אין להפעיל את המאוורר עם להבים או מארז פגומים.
  • מוצר זה מכיל כימיקלים הידועים למדינת קליפורניה כגורמים לסרטן ומומים מולדים או נזקים אחרים למערכת הרבייה (אזהרה לפי הצעה 65).

תכולת חבילה ורכיבים

Verify that all components are present before beginning installation. If any parts are missing or damaged, contact Progress Lighting customer service.

Table 1: Fan Components
רְכִיבתֵאוּרכַּמוּת
שיכון מנועMain body of the fan, containing the motor.1
להבי מאווררFive reversible blades (Cherry/Natural Cherry finish).5
סוגרי להבConnect blades to the motor housing.5
דאודרודSupports the fan from the ceiling.1
חוּפָּהCovers the ceiling electrical box.1
תושבת הרכבהSecures the fan to the ceiling electrical box.1
חבילת חומרהScrews, washers, wire nuts, etc.1
משוך שרשרתFor manual speed control.1
שְׁלַט רָחוֹקFor wireless speed and light control (if applicable).1

התקנה והתקנה

Before installation, ensure the electrical box is securely mounted and capable of supporting the fan's weight (16.4 pounds). A UL listed outlet box marked "FOR FAN SUPPORT" is required.

1. הרכבת המאוורר

  1. כבה את החשמל: נתק את החשמל במפסק הראשי כדי למנוע התחשמלות.
  2. התקנת תושבת הרכבה: Secure the mounting bracket to the ceiling electrical box using the screws provided with the outlet box. Ensure it is firmly attached.
  3. Assemble downrod: Feed the motor wires through the downrod. Attach the downrod to the motor housing.
  4. Hang the fan: Carefully lift the fan assembly and place the downrod ball into the mounting bracket's opening. Ensure the tab in the mounting bracket aligns with the slot in the downrod ball.
Progress Lighting AirPro Collection Builder 52-inch 5-Blade Ceiling Fan, showing the fan assembled with five wooden blades and a brushed nickel motor housing, ready for installation.

Figure 1: Assembled Ceiling Fan (Example)

2. חיבורי חשמל

All wiring must comply with local and national electrical codes. If you are unfamiliar with electrical wiring, consult a qualified electrician.

  1. Connect ground wire: Connect the green wire from the fan to the bare copper (ground) wire from the outlet box.
  2. Connect neutral wire: Connect the white wire from the fan to the white (neutral) wire from the outlet box.
  3. Connect hot wire: Connect the black wire from the fan to the black (hot) wire from the outlet box.
  4. חיבורים מאובטחים: Use approved wire nuts to secure all connections. Ensure no loose strands of wire are exposed.
Close-up of hands connecting electrical wires with wire nuts, demonstrating proper wiring technique for a ceiling fan.

Figure 2: Electrical Wiring Connections

3. חיבור להבי המאוורר

  1. Attach each blade to a blade bracket using the screws provided. Ensure they are securely fastened.
  2. Attach the blade assemblies to the motor housing.
  3. Verify all screws are tightened to prevent wobbling during operation.
דוּ views of a ceiling fan installed, one showing the fan from a distance in a room, and the other a closer view of the fan's motor housing and blades from below.

Figure 3: Installed Ceiling Fan Views

הוראות הפעלה

Your Progress Lighting AirPro Collection Builder ceiling fan can be operated using the pull chain or the included remote control.

Using the Pull Chain

  • Pull the chain once for high speed.
  • Pull the chain a second time for medium speed.
  • Pull the chain a third time for low speed.
  • משוך את השרשרת פעם רביעית כדי לכבות את המאוורר.

שימוש בשלט רחוק

The remote control allows for convenient operation from anywhere in the room. Ensure batteries are installed correctly.

  • לחצני מהירות מאוורר: Press the desired speed button (High, Medium, Low) to adjust fan speed.
  • כפתור כיבוי מאוורר: Press to turn the fan off.
  • כפתור הפעלה/כיבוי אור: If a light kit is installed (sold separately), press to turn the light on or off.
  • Light Dimmer Button: If a dimmable light kit is installed, press and hold to dim or brighten the light.
  • מתג הפוך: Locate the reverse switch on the motor housing (usually near the top). Slide the switch to change the direction of blade rotation for seasonal comfort.
    • מבצע קיץ: Blades rotate counter-clockwise, pushing air down to create a cooling effect.
    • מבצע חורף: Blades rotate clockwise, drawing air up to circulate warm air.

תחזוקה וטיפול

תחזוקה שוטפת תבטיח את אורך חייו וביצועיו האופטימליים של מאוורר התקרה שלכם.

  • ניקוי: נקו את בית המאוורר ואת להביו בעזרת מטלית רכהamp מטלית. אין להשתמש בחומרי ניקוי שוחקים או ממסים, מכיוון שהם עלולים לפגוע בגימור.
  • איזון להב: If the fan wobbles, check that all blade screws are tight. A balancing kit (often sold separately) can be used to correct excessive wobble.
  • שימון מנוע: מנוע המאוורר משומן באופן קבוע ואינו דורש שימון.
  • חיבורי חשמל: בדקו מעת לעת את כל החיבורים החשמליים לאיתנות.

מדריך פתרון בעיות

לפני כל תיקון, יש לוודא שהחשמל מנותק במפסק החשמל.

טבלה 2: בעיות נפוצות ופתרונות
בְּעָיָהסיבה אפשריתפִּתָרוֹן
המאוורר לא מופעלאין חשמל למאוורר; חיבורי חוטים רופפים; נתיך שרוף/מפסק חשמלי מופעל.Check circuit breaker and wall switch; Verify all wire connections are secure; Replace fuse or reset breaker.
מאוורר מתנדנדברגי להב רופפים; להבים לא מאוזנים; תושבת הרכבה רופפת.Tighten all blade screws; Use a blade balancing kit; Ensure mounting bracket is securely fastened to the ceiling box.
פעולה רועשתLoose screws; Motor hum (normal for some fans); Blades hitting an obstruction.Check and tighten all screws; Ensure fan is not hitting anything; If hum is excessive, consult an electrician.
השלט רחוק לא עובדDead batteries; Incorrect frequency setting; Receiver issue.Replace batteries; Ensure remote and receiver dip switches match; Contact customer service if issue persists.

מפרט מוצר

טבלה 3: מפרטים טכניים
תְכוּנָהעֵרֶך
מותגתאורת התקדמות
מספר דגםP2501-09
עיצוב מאוורר חשמלימאוורר תקרה
מידות המוצר52" D x 52" W x 13" H
מספר להבים5
חומר להבPlastic (Cherry/Natural Cherry finish)
סוג גימורNickel (housing)
מהtage64 וואט
כרך ידtage120 וולט
משקל פריט16.4 פאונד
שיטת בקרהPull Chain, Remote
שימוש בפנים/חוץמקורה
מפרט נפגשאנרג'י סטאר
UPC785247114474

אחריות ותמיכה

For warranty information and customer support, please contact Progress Lighting directly. Keep your proof of purchase for any warranty claims.

יַצרָן: תאורת התקדמות

Webאֲתַר: Visit the Progress Lighting Store on Amazon

תאריך זמין ראשון: 24 ביוני 2015

For additional assistance or to purchase replacement parts, please refer to the official Progress Lighting webלאתר או לפנות למחלקת שירות הלקוחות שלהם.

© 2024 Progress Lighting. כל הזכויות שמורות.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.