1. הקדמה
The SJE-Rhombus Tank Alert XT is an advanced indoor/outdoor alarm system designed to provide crucial audio and visual warnings for threatening liquid level conditions. This system is ideal for various applications including lift pump chambers, sump pump basins, holding tanks, sewage systems, agricultural uses, and other non-potable water environments. Its robust design ensures reliable operation and automatic reset functionality once the alarm condition is resolved.

איור 1: The SJE-Rhombus Tank Alert XT system components. This image displays the gray alarm unit with a red beacon on top, a black float switch with its coiled cable, and a metal hose clamp along with two screws for mounting. The alarm unit features a "TANK ALERT XT" label, SJE-Rhombus logo, and a power/silence switch.
2. תכונות עיקריות
- Weatherproof Enclosure: The alarm enclosure meets Type 3R water-tight standard, ensuring durability for indoor/outdoor use.
- Automatic Alarm Reset: The system automatically resets once the liquid level condition returns to normal.
- Horn Silence Switch: Allows the user to silence the audible alarm while the visual beacon remains active until the condition is resolved.
- Alarm Test Switch: Provides a convenient way to test the alarm's functionality.
- High Decibel Alarm Horn: Sounds at 85 decibels at 3 meters (10 feet) to ensure clear notification.
- פעולה עצמאית: When installed on a separate circuit, the alarm system operates even if the pump circuit experiences a failure.
3. מפרטים
| מִפרָט | פְּרָט |
|---|---|
| כרך ידtage | 120 VAC, 50/60 הרץ, 7 וואט מקסימום. (מצב אזעקה) |
| Alarm Enclosure Dimensions | 16.51 x 11.43 x 7.62 ס"מ (6.5 x 4.5 x 3.0 אינץ ') |
| סוג מארז | Indoor/outdoor weatherproof thermoplastic, meets Type 3R water-tight standard |
| צופר אזעקה | 85 decibels at 3 meters (10 feet), meets Type 3R water-tight standard |
| Alarm Beacon | Meets Type 3R water-tight standard |
| מתג בדיקה/שתקה | Certified to IP66 and IP68 standards |
| Float Switch Cable Length | 4.57 meters (15 feet), flexible 18 gauge, 2 conductor (UL) SJOW |
| חומר לצוף | High impact, corrosion resistant PVC housing |
| Float Operating Temperature | עד 60°C (140°F) |
| סוג מתג צף | Hermetically sealed steel capsule with mercury-to-mercury contacts |
| סוג הרכבה | מתקן קיר |
| משקל פריט | 2.99 פאונד |
| מידות המוצר | 6.5 x 3 x 4.5 אינץ' |
4. התקנה והתקנה
Proper installation is crucial for the reliable operation of your Tank Alert XT system. It is recommended that installation be performed by a qualified electrician or technician in accordance with local electrical codes.
4.1. רכיבים נגמרוview
- מתחם אזעקה: Houses the alarm circuitry, horn, beacon, and control switches.
- מתג צף: A liquid level sensor that activates the alarm when a predetermined level is reached.
- חומרת הרכבה: Includes a hose clamp and screws for securing the float switch and alarm unit.
4.2. שלבי התקנה
- תבחר מיקום: Choose a suitable indoor or outdoor location for the alarm enclosure. Ensure it is easily accessible for testing and silencing, and within reach of a 120 VAC power source. The enclosure is designed for wall mounting.
- Mount Alarm Enclosure: Securely mount the alarm enclosure to a flat surface using appropriate fasteners. Ensure it is level and stable.
- Install Float Switch:
- Determine the desired alarm activation level within the tank or basin. The float switch should be positioned so it activates when the liquid reaches this critical level.
- השתמש בהרכבה המצורפת clamp to secure the float switch cable to the discharge pipe or a suitable mounting point inside the tank. Ensure the float can move freely up and down without obstruction.
- Route the float switch cable back to the alarm enclosure, protecting it from damage.
- חיבורי חוטים:
- אַזהָרָה: ודא שהחשמל מנותק לפני ביצוע חיבורים חשמליים כלשהם.
- Connect the float switch wires to the designated terminals inside the alarm enclosure as per the wiring diagram provided with the product packaging.
- Connect the alarm unit to a dedicated 120 VAC power supply. For optimal safety and independent operation, it is recommended to connect the alarm to a separate circuit from the pump.
- מערכת בדיקה: Once all connections are secure and power is restored, perform a system test. Manually raise the float switch to simulate a high liquid level. The alarm horn should sound, and the red beacon should activate. Use the silence switch to confirm it silences the horn, and then lower the float to confirm auto-reset.
5. הוראות הפעלה
The Tank Alert XT system is designed for straightforward operation, providing clear indications of liquid level conditions.
5.1. הפעלת אזעקה
When the liquid level in the tank or basin rises to the point where it activates the float switch, the alarm system will trigger:
- The audible alarm horn will sound at 85 decibels.
- The red alarm beacon on top of the enclosure will illuminate.
5.2. השתקת האזעקה
To silence the audible horn, press the לְהַשְׁתִיק switch located on the front of the alarm enclosure. The horn will cease, but the red alarm beacon will remain illuminated. This visual indicator will stay on until the liquid level returns to normal, signifying that the condition has been remedied.
5.3. Automatic Reset
Once the liquid level drops below the float switch activation point, the system will automatically reset. The red alarm beacon will turn off, and the system will be ready to detect future high-level conditions.
5.4. בדיקת האזעקה
It is recommended to periodically test the alarm system to ensure proper functionality. Press the מִבְחָן switch on the front of the enclosure. This will simulate an alarm condition, activating both the horn and the beacon. Release the switch to return to normal operation.
6. תחזוקה
Regular maintenance helps ensure the longevity and reliability of your Tank Alert XT system.
- בדיקות תקופתיות: Test the alarm system monthly using the TEST switch to confirm both audible and visual indicators are working.
- Float Switch Inspection: Periodically inspect the float switch and its cable for any signs of wear, damage, or buildup that might impede its free movement. Clean the float switch if necessary, especially in applications with viscous liquids or debris.
- Enclosure Check: Ensure the alarm enclosure is free from dirt, moisture, and insect intrusion. Keep the ventilation openings clear if present.
- שלמות כבל: Check all wiring and cables for secure connections and absence of damage.
- ספק כוח: Verify that the alarm unit is continuously receiving power.
פֶּתֶק: Always disconnect power to the alarm unit before performing any maintenance or inspection inside the enclosure.
7. פתרון תקלות
If your Tank Alert XT system is not functioning as expected, refer to the following common issues and solutions:
| בְּעָיָה | סיבה אפשרית | פִּתָרוֹן |
|---|---|---|
| Alarm not sounding/beacon not lighting up during high level or test. | אין חשמל ליחידה. מתג צף לא תקין. חיבור חיווט רופף. יחידת אזעקה פגומה. | בדוק את ספק הכוח ואת מפסק החשמל. Verify float switch operation by manually raising it. Inspect all wiring connections inside the enclosure. Contact SJE-Rhombus support if unit is damaged. |
| אזעקה נשמעת ברציפות. | Liquid level remains high. Float switch stuck in activated position. Faulty float switch or wiring. | Address the high liquid level condition. Inspect float switch for obstructions or debris; clean if necessary. Check float switch and wiring for damage. |
| Alarm horn silenced, but beacon remains off. | Faulty alarm beacon. בעיית חיווט פנימית. | Contact SJE-Rhombus support for repair or replacement. |
| Alarm does not auto-reset. | Liquid level still high. Float switch stuck or damaged. | Ensure liquid level has dropped below activation point. Inspect and clean float switch; ensure free movement. Replace if damaged. |
If troubleshooting steps do not resolve the issue, please contact SJE-Rhombus customer support.
8. אחריות ותמיכה
SJE-Rhombus products are manufactured to high standards and are typically backed by a manufacturer's warranty. Specific warranty terms and conditions, including duration and coverage, are usually provided with the product packaging or can be found on the official SJE-Rhombus webאֲתַר.
For technical assistance, warranty claims, or to purchase replacement parts, please contact SJE-Rhombus customer support directly. Have your product model number (1005481) and date of purchase available when contacting support.
SJE-Rhombus Official Webאֲתַר: www.sjerhombus.com
Please note that product specifications and features are subject to change without notice. Always refer to the latest documentation provided by the manufacturer.